Quick Detail:
12V5A CCTV power, 9 channels output, Independent LED indicator with each output. 100-240VAC or115V/230VAC input.
Brand Name : W&T
Competitive Advantage:
High efficiency power
LED indicator
Independent LED indicator with each output
Over load & short circuit protection
100% full load burn-in test
2 Years warranty
Application:
It’s suitable for an extremely wide range of applications, including:
• shelter camera adapter
• Wireless CCTV camera charger
• waterproof infrared camera adpater
• Wireless Burglary Alarm charger
• Digital camera
• Electronics Toy
• IP camera adapter
• GSM alarm system adapter
• intercom system adapter
• CCTV Camera , IP Camera , PTZ ,IR Illuminator , DVR,LED Dricer ,Access Control;
Building visual system power supply,Illuminator system etc.
Model No. |
W&T-TVP1205-T9 (9 Channel output) |
|||||||||||||||||||
Outputs channels |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
||
Output |
DC Voltage (V) |
12V |
12V |
12V |
12V |
12V |
12V |
12V |
12V |
12V |
||||||||||
Rated Current (A) |
0.66A |
0.66A |
0.66A |
0.66A |
0.66A |
0.66A |
0.66A |
0.66A |
0.66A |
|||||||||||
LED indicator |
LED |
|||||||||||||||||||
Ripple wave & noise(MV) |
120mV |
|||||||||||||||||||
Voltage Accuracy(%) |
±5% |
|||||||||||||||||||
Total output current |
5.0A |
|||||||||||||||||||
Thermal Cutoffs Protection(TCO) |
Each output has independent PTC fuse and LED indicator , when problem occurs, only affect the independent output ,other output still working . |
|||||||||||||||||||
Rise time |
1800ms,23ms/230VAC 4000ms,30ms/115VAC at full load |
|||||||||||||||||||
Hold up time (TYP.) |
80ms/230VAC 14ms/115VAC at full load |
|||||||||||||||||||
Input |
Volrage range |
100V-240V AC; (86V-265V AC) |
||||||||||||||||||
Frequency range |
47~63Hz |
|||||||||||||||||||
Efficency (Typ.) |
>80% |
|||||||||||||||||||
Protection |
Over load |
110-180%rated output power ,protection type:hiccup mode,recovers automatcally after fault condition removed |
||||||||||||||||||
Over Current |
When the over current occurs(Average output current 130-150%), the power supply will automatically switch to self-protection status, when condition removed,then switch back to normal . |
|||||||||||||||||||
Over voltage |
0ver voltage set : 120-140% rated voltage |
|||||||||||||||||||
Short circuit |
When short condition occurs, independent PTC fuse will open the circuit,when condition removed , PTC fuse will automatically back to close . |
|||||||||||||||||||